HTMLText_0F87460C_267B_FE95_41B3_A209933A58F1.html =
Conference Room
The Conference Room is equipped with audio/visual ammenities with space to accomodate 25+ people for collaborative meetings. Reservations are available free of charge through the Equinix Customer Portal.
HTMLText_28868B4F_263B_2FF4_41BD_BCF27CB5EF6B.html = Concrete Floor
The main colocation floors are the core of each Equinix IBX data center. Equipment is located in secure private or secure shared environments. Each location provides for robust interconnection among tenants to ensure direct, private exchange of IT traffic with a diverse set of counterparties and providers at distributed IT exchange points inside the carrier-neutral facility.
Most Equinix IBX data centers leverage a multi-tiered overhead cabling system to deliver interconnection solutions throughout the facility.
HTMLText_629B9668_7E0D_EFE3_41B7_914EB6D2F919.html =
HTMLText_70977347_6F02_3B4F_41CB_E3E96CD61219.html = Fire Supression Gas Cylinder
HTMLText_7929CC5B_5A68_5966_41C0_CC46E4C1A4AA.html =
HTMLText_8F65F99F_985C_35B3_41CE_4A14961E464F.html = Conference Room
The Conference Room is equipped with audio/visual ammenities for collaborative meetings. Reservations are available free of charge through the Equinix Customer Portal.
HTMLText_9209E433_B9FB_A92B_41D1_F5F8BD957235.html = Fiber Path
Equinix data centers contain diverse fiber entry points into the building through which our network customers run their fiber.
These diverse fiber paths help to ensure maximum network uptime. In addition, the fiber paths connect this IBX facility to neighboring IBXs, delivering interconnected access between all Equinix customers within the metro area.
HTMLText_9229BD7A_BE2D_9B24_41B1_C06CA14F9D17.html = Antenna
Many sites are equipped with rooftop areas where customers can install their GPS, line of sight or dish antenna.
HTMLText_9271DB6A_B9E4_9F24_41C2_37F57349907B.html =
HTMLText_92FD9C5E_BE3B_791D_41E1_A55F5DB052C2.html =
HTMLText_99CDE0BA_B9DC_A925_41E4_2C84DCD49CC5.html =
HTMLText_9A45032F_BA27_6F3B_41D1_65E288667157.html =
HTMLText_9A4D5FF3_BA25_772B_41AC_95542D9A8570.html =
HTMLText_9A4F57D7_BA64_976B_41B0_FE34799DD8BD.html = Mantrap
To reach the data center floor, every Equinix visitor must pass through a series of interlocking doors and travel through a mantrap. The mantrap can only be accessed via two sets of automatic doors, one of which opens to the lobby, the other to the customer circulation area. The doors are made of bulletproof Lexan and are never open at the same time.
HTMLText_9ABD4248_BA5B_A965_41E5_AF06CEA2B2C5.html = Customer Care
The customer care area is a dedicated space where customers can conduct business or take a break. Conference rooms provide private meeting areas via an online reservation process, free of charge.
A customer break area offers vending machines with coffee and snacks, as well as tables and chairs. Online access is available as are private customer workstations in a convenient, shared work environment. For more information, see the Customer Guide.
HTMLText_9ACE7154_BA3B_EB6D_41C1_DB245266D8CC.html = Customer Work Stations
Private customer work stations are available in a convenient, shared work environment.
HTMLText_9B084998_BA7D_9BE4_4199_D37330C17940.html = Our International Business Exchange™ (IBX®) data centers offer 24/7/365 security and customer access, along with a global uptime record of 99.9999%.
Structurally, not all of our facilities are identical—some were built from the ground up while others were acquired or developed in existing spaces.
Equinix is also vendor-neutral, meaning we welcome all service providers inside our data centers, with no preference given to any single vendor. That attracts a broad selection of service providers and their potential partners to our facilities, creating countless opportunities for interconnection. We also offer expert guidance to these companies in order to help them make an informed data center decision.
HTMLText_9B1CB0DF_BA64_E91B_41E0_3581DCC3F9B4.html = Security Lobby
Within the Security Lobby, visitor identity must be verified with valid government-issued photo identification.
An intrusion detection system monitors all ingress/egress points throughout the facility, while on-premises security personnel physically monitor the facility.
HTMLText_9B599685_BA6C_A9EC_41D4_CC4AF9C1DC4A.html = Prior to entry into an IBX facility, authorized access is required. Access enrollment types, security profiles and visitor permissions can be managed within the Equinix Customer Portal.
Authorized visitors may use a proxy card with biometric verification for entry into the facility. Authorized access can be set up as permanent permission for 24x7x365 access or with temporary admittance for a specified date/time.
HTMLText_9CF1617A_BA2D_AB25_41E7_220525D0DCEF.html = IBXflex Office Space
IBXflex® allows customers to build dedicated office or storage space within or near our IBX data centers. IBXflex space comes with 24-hour on-site IBX access, and has the same security, fire suppression and environmental controls as any space inside an Equinix data center.
HTMLText_9CF444EA_B9E5_A925_41E3_48E4A3EE0FF1.html =
HTMLText_9CFA57B8_B9E4_B725_41A2_1D064FC53A38.html = Uninterruptible Power Supply (UPS)
In order to meet the high uptime requirements for data centers, Uninterruptible Power Supply (UPS) systems are often deployed with redundancy.
Each system of interlocking electrical equipment ensures that continuous power flows to all facility equipment in the case of an outage. The standby UPS systems ensure the seamless transition between grid power, battery backup and generator power in the event of common power problems.
HTMLText_9D014ADD_B9FC_991F_41E6_9E87C69F4E88.html = Fire Detection and Suppression Systems
Every IBX has a very early smoke detection alarm system, called VESDA for short. The system samples the air at adjustable periods of time, and if the sample is different from a reference sample the machine has taken, an alarm is activated. But water in the dry-pipe system isn’t released until a sprinkler head valve opens, and that requires a temperature of 165 degrees at the sprinkler location. The water is then released only in the area of the fire, and if there’s a false alarm, we have auxiliary drains, so we can safely empty the water out of the facility.
HTMLText_9D4C41DF_B9E4_AB1C_41D8_DD74077B2A0E.html =
HTMLText_9D4E65E3_B9FC_AB2B_41DE_8EC4C123302E.html =
HTMLText_9D557750_B9FD_B765_41CE_946D7491E5A6.html = Electrical
Our power systems are designed and managed to perform against rigorous testing and operational processes, with fully documented maintenance procedures at each site.
Equinix engineers also use proprietary automated telemetric systems to continuously monitor all power system components at our data centers, ensuring quick response times and effective support.
HTMLText_9D64A71C_BA25_971D_41DB_DAD7C6F215EC.html = Raised Floor
The main colocation floors are the core of each Equinix IBX data center. Equipment is located in secure private or secure shared environments. Each location provides for robust interconnection among tenants to ensure direct, private exchange of IT traffic with a diverse set of counterparties and providers at distributed IT exchange points inside the carrier-neutral facility.
Several of our data centers use a traditional “raised floor” system, where the floor panels are removed and cables are snaked in underneath, as opposed to a system where cables are installed overhead.
HTMLText_9DA09F59_BE2C_B766_41B2_5B4587A314CE.html = Rooftop facilities are critical to IBX operations in many ways. Cooling, antenna locations and other infrastructure contribute to the smooth operation of the building.
HTMLText_9DA2D70F_BA2B_A8FB_41D3_6C6591219877.html = Operations Center
Our operations center is staffed 24 hours a day to ensure that everything inside the data center is running smoothly. The center monitors the essential systems inside our data centers, including the environment, air flow, power backup and fire suppression.
We also have engineering expertise and subject-matter experts on staff to handle emergency maintenance and preparedness for all key infrastructure components. All of this is tracked from a single, central location and then networked to Equinix headquarters.
HTMLText_9DAC7BBF_BE2C_BF1C_41E0_09FE317FEBC2.html = Shipping and Receiving
Our IBX Operations staff receives and ships equipment through our loading docks. Customers have the option to get boxes delivered to their cage through our standard Equinix Smart Hands® service, while rack and stack is available through Smart Hands custom ordering.
HTMLText_9DCA3786_BA3B_97ED_41D2_6BC44E752F59.html = Breakroom
Take a break and unwind. Our customer break areas offer vending machines and kitchen facilities with coffee and snacks, as well as tables, chairs and other amenities.
HTMLText_9DE9D9DB_BA5D_7B64_41D5_D9ADF419E344.html =
HTMLText_9DF95BCF_BE2B_BF7B_41C9_63128A2E9038.html = Cooling Stacks
Maintain suitable environmental conditions for our customer deployments.
HTMLText_9E37D6AB_B9DC_A924_41C2_28F50AB14F27.html = Overhead Tamper-Proof Cable Tray System and Cable Management
HTMLText_9E50A627_B9ED_A92B_41C9_4772E2E195D5.html = Secure Cabinet
Individual locked cabinets provide secure, dedicated, space and power capacity within an area shared by multiple Equinix customers. Each secure cabinet includes:
Demarcation point within the cabinet, allowing Equinix to deliver interconnection securely.
Optional cabinet accessories such as cabinet shelves and cable management.
High power-density (upon special approval.)
HTMLText_9E51A1E0_B9DB_AB25_41E2_CAFC50690066.html = Cage Wall
Built-to-order space based on planned power capacity and cabinet quantity.
HTMLText_9EDAF3A5_B9EF_6F2F_41E1_32840D0E899D.html = Cabinet Door
Lockable, fully ventilated doors which may be configured for left- or right-window.
Closed 4-post cabinet with adjustable-depth rails.
HTMLText_9F609359_B9EB_AF64_41E2_86D609D82D16.html =
HTMLText_9F8715E4_B9E5_6B2D_41D9_260CCF474A5D.html = Demarcation Panel
Demarcation points allow Equinix to deliver interconnection to the cage, providing each customer full control over their connections.
HTMLText_B9BFF8BC_8D85_5590_41AF_513D83C0B83E.html =
### Tooltip
IconButton_40D1CF05_5278_5B71_41CC_0013BFADF3D9.toolTip = Toggle Gallery
IconButton_40D1CF05_5278_5B71_41CC_0013BFADF3D9_mobile.toolTip = Toggle Gallery
IconButton_4119B4DD_5188_2E91_41B4_DB380EBC26F2.toolTip = Look Down
IconButton_4119B4DD_5188_2E91_41B4_DB380EBC26F2_mobile.toolTip = Look Down
IconButton_4185A425_5278_2DB1_41C3_641F043D200A.toolTip = Toggle Fullscreen
IconButton_4185A425_5278_2DB1_41C3_641F043D200A_mobile.toolTip = Toggle Fullscreen
IconButton_41E822ED_5388_EE8B_41CD_EB27B81427B2.toolTip = Next Panorama
IconButton_41E822ED_5388_EE8B_41CD_EB27B81427B2_mobile.toolTip = Next Panorama
IconButton_41E842ED_5388_EE8B_41B7_EA16C2B0C826.toolTip = Look Right
IconButton_41E842ED_5388_EE8B_41B7_EA16C2B0C826_mobile.toolTip = Look Right
IconButton_41E8C2ED_5388_EE8B_41C0_06430D6A3CE9.toolTip = Zoom In
IconButton_41E8C2ED_5388_EE8B_41C0_06430D6A3CE9_mobile.toolTip = Zoom In
IconButton_41E942E7_5388_EE87_41C9_BDCA41DE74FD.toolTip = Zoom Out
IconButton_41E942E7_5388_EE87_41C9_BDCA41DE74FD_mobile.toolTip = Zoom Out
IconButton_41E992ED_5388_EE8B_41CD_4C69F9CCA85C.toolTip = Look Up
IconButton_41E992ED_5388_EE8B_41CD_4C69F9CCA85C_mobile.toolTip = Look Up
IconButton_41E9E2E8_5388_EE89_41CC_948883A3BE45.toolTip = Look Left
IconButton_41E9E2E8_5388_EE89_41CC_948883A3BE45_mobile.toolTip = Look Left
IconButton_42EB111E_5288_2B89_41D4_AB07275D9789.toolTip = Previous Panorama
IconButton_42EB111E_5288_2B89_41D4_AB07275D9789_mobile.toolTip = Previous Panorama
Image_4C29BA57_FA27_64A6_41C2_8C6128036ABD.toolTip = Forward
Image_4C29BA57_FA27_64A6_41C2_8C6128036ABD_mobile.toolTip = Forward
Image_7CBECF07_FA27_9CA7_41D6_2E3CA7A24B44.toolTip = Backward
Image_7CBECF07_FA27_9CA7_41D6_2E3CA7A24B44_mobile.toolTip = Backward
## Media
### Title
panorama_907595D6_B260_E061_41D7_799DFD1F83F5.label = Roof
panorama_A3C91494_B1A1_E0E1_41E4_C4186548EAF4.label = Loading Dock 1
panorama_A3C951B6_B1A0_6021_41E5_6C9AE06245CE.label = IBX Exterior 2
panorama_A3C9547F_B1A0_601F_41D3_96CA0C02CAA4.label = IBX Exterior 1
panorama_A3CB92BB_B1A0_6027_41D8_2CF77DCE0C1B.label = Customer Entry 1
panorama_A3CBD148_B1A0_2061_41E4_1E4216235DC1.label = Chiller Plant Room
panorama_A3CBE367_B1AF_E02F_41D4_D5056D54CCE5.label = Batteries
panorama_A3CC4345_B1A0_6063_41E5_CDECEDEFD80E.label = Cooling
panorama_A3CC71A9_B1A0_2023_41DA_562185121B00.label = Customer Lounge
panorama_A3CC7232_B1A0_2021_41AF_B7F7DDB12098.label = Customer Entry 2
panorama_A3CC80DB_B1A0_E067_41E2_740464DED39E.label = Generator
panorama_A3CCE161_B1A0_E023_4189_8CB19EE23B96.label = Fiber Room
panorama_A3D6E2E8_B1A0_2021_41D4_0080EC9C3A15.label = Colocation Floor 1
panorama_A3D70389_B1A0_60E3_41DA_3591C0E19127.label = Switchgear 2
panorama_A3D7137E_B1A0_2021_41DB_E4E64A1D35AD.label = Electrical
panorama_A3D73285_B1A0_20E3_41CE_B0197ED797C9.label = Switchgear 1
panorama_A3D765C5_B1A0_2063_41BD_8F45F57D5617.label = Loading Dock 2
panorama_A3D77289_B1A0_60E3_41C7_639736006418.label = IBX Hallway
panorama_A3D7A663_B1A0_E027_41E0_998282A4FEA3.label = Conference Room 1
panorama_AC36AFE4_B1A0_E021_41CE_A54ABC4AF45C.label = Conference Room 2
panorama_AE454D79_B1A0_6023_41D5_E46F094402CA.label = Security Lobby
panorama_C0774179_D690_7FBF_41D3_D14855902AB0.label = Mantrap
panorama_C1C6D7E0_D690_82CD_41E5_5F058617E9C0.label = LOCC
panorama_C2A8297E_D690_8FB5_41D3_44F89FF021CB.label = Secure Cabinets
panorama_C3DD4ECF_D691_82D3_41B5_6A3D35CA3108.label = Private Cage
panorama_C57A8841_D697_8DCF_41E7_CCC1753A172B.label = Colocation Floor 2